Marsh-McBirney FLO-DAR™ with Flo-Station™ Radar Velocity/Area Flow Meter
|
Specifications
FLO-DAR SENSOR (Without SVS)
Enclosure
IP 68 Waterproof rating, Polystyrene
Dimensions
160.5 W x 432.2 L x 297 D mm (6.32 x 16.66 x 11.7 in.), with SVS, D = 387 mm (15.2 in.)
Weight
4.8 kg (10.5 lbs.)
|
 |
Operating Temperature
-10 to 50°C (14 to 122°F)
Storage Temperature
-40 to 60°C (-40 to 140°F)
Power Requirements
Supplied by Flo-Station
Interconnecting Cable
ˆDisconnectable at both sensor and logger
Polyurethane, 0.400 (±0.015) in. diameter; IP68
Standard length 9M (30 ft), maximum 305 m (1000 ft)
Certification
FCC Rules Part 15, Subpart C; Industry Canada RS-S210
(No user license required)
SURCHARGE DEPTH MEASUREMENT
Auto zero function maintains zero error below 0.5 cm (0.2 in.)
Method
Piezo-resistive pressure transducer with stainless steel diaphragm
Range
3.5 m (138 in.), overpressure rating 2.5 x full scale
VELOCITY MEASUREMENT
Method
Radar
Range
0.23 to 6.10 m/s (0.75 to 20 ft/s)
Frequency Range
24.075 to 24.175 G-Hz, 15.2mW (max.)
Accuracy
±0.5%; ±0.03 m/s (±0.1 ft/s)
DEPTH MEASUREMENT
Method
Ultrasonic
Standard Operating Range from Flo-Dar Housing to Liquid
0 to 152.4 cm (0 to 60 in.)
Optional Extended Operating Range from Transducer
Face to Liquid
0 to 6.1 m (0 to 20 ft.) with 43.18 cm (17 in.) dead band, temperature compensated.
Accuracy
±1%; ±0.25 cm (±0.1 in.)
FLOW MEASUREMENT
Method
Based on Continuity Equation
Accuracy
±5% of reading typical where flow is in a channel with uniform flow conditions and is not surcharged, ±1% full scale max.
SURCHARGE CONDITIONS DEPTH/VELOCITY
DEPTH (Std with Flo-Dar Sensor)
Surcharge depth supplied by Flo-Dar sensor.
VELOCITY (Optional Surcharge Velocity Sensor)
Method
Electromagnetic
Range
±4.8 m/s (±16 ft/s)
Accuracy
±0.15 ft/s or 4% of reading, whichever is greater.
Zero Stability
> ±0.05 ft/s
FLO-STATION PERMANENT AC/DC POWERED ELECTRONICS
Data Storage
64K (16K cycles of velocity/depth data)
Local Terminal
RS232C at 19.2K baud
Optional Display
Dimensions: 1 in. x 3 in. Four lines of text display, FLOW, LEVEL, VELOCITY, FLOW TOTAL or any combination of any four channels containing data. Screens may be programmed to alternate values displayed.
Time-Based Accuracy
1 second per day
Outputs
Four 4-20 mA outputs: system-isolated, up to 600 ohm load. Outputs are flow, level, velocity or surcharge level.
Contact Closure
Dry contact closure with adjustable duration selectable for flow-proportional or alarm based on: FLOW, LEVEL, VELOCITY, SURCHARGE LEVEL, TEMPERATURE, BATTERY VOLTAGE, EACH SAMPLE, BAD SAMPLE OR ANALOG INPUT.
Rating: 1A @ 30 Vdc (resistive) 0.5A @ 125 Vac (resistive)
Power Requirements
AC: 85-264 Vac, 47-63 Hz, 32 watts
DC: 12 Vdc for Flo-Station without display or Flo-Station with display (backlight off) 180 mA (2.1 watts) with (1) 4-20 mA utilized.
Housing
Material: ABS plastic, NEMA 4
Dimensions: 257.8 W x 236.7 H x 95.3 D mm (10.15 W x 9.32 H x 3.75 D in.)
Weight: 2.3 kg (5 lbs)
Operating Temperature
Operating Range: -10 to 50°C (14 to 122°F)
-20 to 50°C (-4 to 122°F) without display
Storage Temperature
Without Display: -40 to 60°C (-40 to 140°F)
With Display: -20 to 60°C (4 to 140°F)
Set-up/Data Retrieval
Flo-Ware for Windows software is the user on-site set-up, data management, and report generation software. It is compatible with desktop/portable computers utilizing Windows 95/98/2000/Me/NT/XP. Flo-Ware FX for PocketPC has all the same functionality as Flo-Ware for Windows with the exception of report generation.
|