Search
Products/Services
Flow Meters – Open Channel
Flo-Tote™ 3 Flow Meter
Flo-Tote™ 3 Overview Page
Request Quote / More Info
Rental Information
Specifications
» Flo-Tote™ 3 Specifications
Literature Download
Flo-Tote™ 3 brochure
Flo-Tote™ 3 sensor manual
Spring band for Flo-Tote 3 sensor installation
Partial band for Flo-Tote 3 sensor installation
Scissor-jack band for Flo-Tote 3 sensor installation
Rectangular mount for Flo-Tote 3 sensor installation
Q-Stick Installation of Flo-Tote 3 sensor with spring-band

Flo-Tote™ 3 Specifications

SENSOR

Velocity Measurement

• Method: Electromagnetic (Faraday’s Law)

• Range: -5 to +20 feet per second (-1.5 to +6.1m/s)

• Accuracy: ±2% of reading, ± 0.05 zero stability at 0 to +10 ft/sec (0 to + 3m/sec)

• Zero Stability: ±0.05 feet per second (±0.015m/sec)

• Resolution: 0.01 feet per second (± 0.003m/sec)


Level Measurement

• Method: Submerged pressure transducer

• Range: Standard 0.4 to 138 inches. (10mm to 3.5m) Optional 0.4 to 276 inches

• Accuracy: ±1% of reading

• Zero Stability: ± 0.03 ft. (± 0.009m) zero stability for 0 to 10 ft (0 to 3m). Includes non-linearity, hysteresis and velocity effects.

• Resolution: 0.1 inch (2.5mm)

• Over Range Protection: 2 X range

Flow Measurement

• Method: Conversion of water level and pipe size to fluid area. Conversion of local velocity reading to mean velocity. Multiplication of fluid area by mean velocity to equal flow rate.

• Conversion Accuracy: ±5.0% of reading. Assumes pipe is 10 to 90% full and with a level greater than 2 inches


Temperature Measurement:

• Method: 1 wire digital thermometer

• Range: 14º to 185ºF (-10º to 85ºC)

• Accuracy: ± 6 F (3.5ºC) degrees


Material

• Standard: Polyurethane

• Dimensions: 5 3/16"(131.8mm) L, 1 ¾ " (44.5mm)W, 1 1/8" (29mm)H

• Weight: 2.5 lbs. (with 30 feet of sensor cable)

• Operating Temperature Range: 32° to 113°F (0° to 45°C)

• Storage Temperature: -4º to 125ºF (-20° to 52°C)


Sensor Cable

• Material: Polyurethane jacketed

• Standard Length: 30 ft. (9m)

• Optional Length: 60 ft. (18m),100 ft. (30m) or length as needed (maximum 1000 ft/300m)


FLO-LOGGER

Data Storage: 64K (16K cycles of velocity/level data)

Local Terminal: RS232C at 19.2K baud

Power Requirements: Two 6-volt lantern batteries

Battery Life: Typical - 16 weeks at a sample interval of 15 minutes (with recommended batteries)

Housing: Sealed watertight PVC – meets IP68 rating

Length: 13.85 in. (35.179 cm)

Diameter: 7.75 in. (19.685 cm)

Weight: 7.5 lbs. (3.4 kg) (including batteries)


Temperature

• Operating Range: 14°F to 125°F (-10°C to 51°C)

• Storage Temperature Range: -4°F to 125°F (-20°C to 51°C)


Sensor/Logger Disconnect

Both the sensor and the logger have waterproof (IP68) connectors for easy separation from the interconnecting cable.


Certification

• FCC Rules Part 15

• Industry Canada RSS 210

• No user license required

FLO-STATION

Data Storage: 64K (16K cycles of velocity/level data)

Local Terminal: RS232C at 19.2K baud

Outputs: (4) 4-20 mA isolated outputs scaleable to desired values and capable of sinking 50 ohms each. Contact Closure (One from C dry).

Power Requirements: +12VDC @220 mA with three 4-20mA outputs @ 20Ma

Housing: NEMA 4X (IP66/67-7)

Material: Polystyrene

Dimensions: 9 in. W x 7 in. H x 4 in. D (229 mm W x 178 mm H x 102 mm D)

Weight: 2.75 lbs. (1.25 kg)


Temperature

• Operating Temperature Range: 14° to 122°F (-10°C to 50°C)

• Storage Temperature Range: -4° to 122°F (20°C to 50°C)

Contact factory for Sensor Mounting Hardware Ordering Information